XM31-915-HP - 10018235
Components
Alarms
Battery
Log In...
English
Español
Français
Português
Deutsch
Overview
Hardware
Power Supply
Batteries
Environmental I/O
Components
Network
Ethernet
Advanced
Interfaces
Network Services
Management
System Data
SNMP
Alarms
Utility Power
History
Power Supply Events
Power Supply Configuration
Battery Events
Standby Events
Alarm Log
st,md,pn,sn,fw,bl,cf,ma
Components
Status
Model
Part Number
Serial Number
Firmware Version
Bootloader Version
Configuration
MAC Address
Alpha Power Supply
XM31-915-HP
017-950-20-001
2406F0400708
PS3.1-v01.07.00 b008
X6A9F0UEH205.02ABA000
eCMM
CMOA-4285F
746-856-22-001 E
2315F71C4351
RDKB 0.91.00 [7.2.5.0.207]
CGM2.86C.627077.R.1912091521
PS31NA0DP04M
00:90:EA:32:1D:B7
ARM Core
4.9.229
Atom Core
4.9.229-yocto-standard
Application
PS3.1-v01.07.00 b008
EMM
Online
704-00302-30-001 L
A012342F19T0153
V2.06.0
V2.01.0
49
PCM
Online
704-00301-20-002 C
A012341F19B3126
V2.06.0
V2.01.0
18
PPM
Online
704-993-20-002 B
A012341F19J2629
3
Transformer
241-181-19-001 E
1812343F7000156
Oil Cap
100200
843425
PDM
Online
704-987-20-003 C
A012340F19G1562
4
SAG
Online
704-982-21-002 G
A012339F19X0596
34
Inverter Module
746-889-21-002
A012344F19A1000
X6A9F0UEH205.02ABA000
RDK-B
rdkb-20200424
c,i
Temperature Readings
Current
Initial
Puma SoC
53.00
°C
127.40
°F
75.00
°C
167.00
°F
Puma ARM
50.00
°C
122.00
°F
74.00
°C
165.20
°F
Puma Atom
50.00
°C
122.00
°F
74.00
°C
165.20
°F
EMM MCU
32.74
°C
90.93
°F
Inverter
26.27
°C
79.29
°F
Battery
9.00
°C
48.20
°F
→ CSV